• 1LE1601-1CC33-4AF4-Z Q01+S03

    SIMOTICS SD MOTOR TYPE: 1CV2133C LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 6POLE * FS132M * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP Q01=MEASURING NIPPLE FOR SPM SHOCK PULSE MEASUREMENT TO MONITOR BEARINGS S03=SPECIAL PAINT FINISH IN SEA AIR RESISTANT

  • 1LE1601-1CC33-4AF4-Z D22+D47+Q01+S03+R16

    SIMOTICS SD MOTOR TYPE: 1CV2133C LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 6POLE * FS132M * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION Q01=MEASURING NIPPLE FOR SPM SHOCK PULSE MEASUREMENT TO MONITOR BEARINGS S03=SPECIAL PAINT FINISH IN SEA AIR RESISTANT R16=CABLE GLAND, MAXIMUM OF CONFIGURATION

  • 1LE1601-1CC33-4AF4-Z D22+D47+Q01+R16+S03

    SIMOTICS SD MOTOR TYPE: 1CV2133C LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 6POLE * FS132M * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION Q01=MEASURING NIPPLE FOR SPM SHOCK PULSE MEASUREMENT TO MONITOR BEARINGS R16=CABLE GLAND, MAXIMUM OF CONFIGURATION S03=SPECIAL PAINT FINISH IN SEA AIR RESISTANT

  • 1LE1601-1CB62-2GB4-Z F70+G02+H00+M01

    SIMOTICS SD MOTOR TYPE: 1CV2136B Low-voltage motor, IEC Squirrel-cage rotor, self-ventilated, IP55 Temperature class 155(F) according to 130(B) Cast iron frame, increased power Performance line High Efficiency IE2, In EEA: Minimum efficiency according to applicable statutory regulations to be considered! 4-pole * Size 132M, * 11kW (50 Hz) 12.6kW (60 Hz) 3 AC 50 Hz 230 VD/400 VY * 3 AC 60 Hz 460 VY IM V 1 without canopy, flange: FF265 (A300) 3 PTC thermistors for disconnection (2 terminals) Terminal box at top F70=Mounting of external fan G02=Mounting of rotary pulse encoder 1XP8012-20 (TTL) 1024 pulses, with external fan (F70) the 1XP8032-20 is used H00=Canopy M01=Connected in star for dispatch

  • 1LE1601-1CB23-3AG4-Z B02+F01+F10+F50+H00+H07+N05+R10+S04+Y56

    SIMOTICS SD MOTOR TYPE: 1CV2132B LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, IN EEA: CONSIDER EFFIC. GRADE ACC. TO CURR. VALID REGULATION! 4POLE * FS132M * 7.5KW (50HZ) 8.6KW (60HZ) 3 AC 50HZ 380VD/660VY * 3 AC 60HZ 440VD IM B 3, 2 temperature sensor KTY84-130 (4 terminals) TERMINAL BOX AT TOP B02=TEST CERTIFICATE 3.1 ACCORDING TO EN 10204 F01=MOUNTING A BRAKE INCL. MOUNTING COSTS F10=BRAKE SUPPLY VOLTAGE 24 V DC F50=MECHANICAL MANUAL BRAKE RELEASE WITH LEVER H00=PROTECTIVE COVER H07=RUST-RESISTANT SCREWS (EXTERNAL) N05=TEMPERATURE CLASS 155 (F), UTILISED TO 130 (B), COOLING MEDIUM TEMPERATURE 45 DEG. C, DERATING APPROX. 4% R10=TERMINAL BOX ROTATED T. 90 DEG. CABLE ENTRY FROM DE S04=SPECIAL COATING OFF-SHORE, Y56=PAINT FINISH IN SPECIAL RAL COLOURS (SELECTION SEE CATALOG) RAL….

  • 1LE1601-1CB09-0GB4-Z B02+F01+F12+F70+H00+M1D+N11+R11

    SIMOTICS SD motor type: 1CV2130B low-voltage motor, IEC squirrel-cage rotor, self-cooled, IP55 temperature class 155(F) according to 130(B) gray cast iron housing performance line in EEA: minimum efficiency acc. to applicable statutory regulations to be considered! (as of 01.01.2017) High Efficiency IE2, 4-pole * frame size 132S, * 5.5 kW (50 Hz) 6.3 kW (60 Hz) standard color RAL 7030, if no order code is specified for selecting another color. 3 AC 60 Hz 440 VD * 60 Hz power IM V 1 without canopy, flange: FF265 (A300) 3 PTC thermistors for disconnection (2 terminals) Terminal box at top B02=Acceptance test certificate 3.1 according to EN 10204 F01=Built-on brake incl. mounting costs F12=Brake control voltage 400 V AC, 50/60 Hz F70=Mounting of external fan H00=Canopy N11=Temperature class 180(H) utilized according to 155(F) with rated power and max. CT 60? R11=Terminal box rotated by 90?, entry from NDE (non drive end)

  • 1LE1601-1CB03-4AF4-Z D22+D47+G04+Q01+G43+R16+S03

    SIMOTICS SD MOTOR TYPE: 1CV2130B LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 4POLE * FS132S * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION G04=MOUNTING A ROTARY PULSE ENCODER LL 861 900 220, 1024 I (LEINE & LINDE) 1024 PULSES PER REV. MOUNTING COST INCLUDED W. UNIT Q01=MEASURING NIPPLE FOR SPM SHOCK PULSE MEASUREMENT TO MONITOR BEARINGS G43=PROTECTIVE COVER FOR ENCODER (ENCL. LOOSE) R16=CABLE GLAND, MAXIMUM OF CONFIGURATION S03=SPECIAL PAINT FINISH IN SEA AIR RESISTANT

  • 1LE1601-1CB03-4AF4-Z D22+D47+G04+G43+Q01+R16

    SIMOTICS SD MOTOR TYPE: 1CV2130B LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 4POLE * FS132S * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION G04=MOUNTING A ROTARY PULSE ENCODER LL 861 900 220, 1024 I (LEINE & LINDE) 1024 PULSES PER REV. MOUNTING COST INCLUDED W. UNIT G43=PROTECTIVE COVER FOR ENCODER (ENCL. LOOSE) Q01=MEASURING NIPPLE FOR SPM SHOCK PULSE MEASUREMENT TO MONITOR BEARINGS R16=CABLE GLAND, MAXIMUM OF CONFIGURATION

  • 1LE1601-1CB03-4AF4-Z D22

    SIMOTICS SD MOTOR TYPE: 1CV2130B LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 4POLE * FS132S * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR TEMPERATURE DETECTION KTY 84-130 TERMINAL BOX AT TOP D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)

  • 1LE1601-1CB03-4AB4-Z B02+F76+Y59

    SIMOTICS SD MOTOR TYPE: 1CV2130B LOW-VOLTAGE MOTOR, IEC SQUIRREL-CAGE,SELF-VENTIL.,IP55 TEMP. CL. 155(F) ACC.TO 130(B) CAST-IRON HOUSING PERFORMANCE LINE HIGH EFFICIENCY IE2, 4POLE * FS132S * 5.5KW (50HZ) 6.3KW (60HZ) 3 AC 50HZ 400VD/690VY * 3 AC 60HZ 460VD IM B 3, MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN TERMINAL BOX AT TOP B02=TEST CERTIFICATE 3.1 ACCORDING TO EN 10204 F76=EXTERNAL METAL FAN Y59=NON-STANDARD CYLINDRICAL SHAFT EXTENSION, NDE

  • 1LE1601-1CA02-2AB4

    SIMOTICS SD motor type: 1CV2130A low-voltage motor, IEC squirrel-cage rotor, self-cooled, IP55 temperature class 155(F) according to 130(B) gray cast iron housing performance line in EEA: minimum efficiency according to (EU) 2019/1781 is IE3 (as of 01.07.2021) High Efficiency IE2, 2-pole * size 132S, * 5.5 kW (50 Hz) 6.3 kW (60 Hz) standard color RAL 7030, if no order code is specified for selecting another color. 3 AC 50 Hz 230 VD/400 VY * 3 AC 60 Hz 460 VY IM B 3, 3 PTC thermistors for disconnection (2 terminals) Terminal box at top

  • 1LE1601-1BB23-4AB4-Z B02

    SIMOTICS SD MOTOR TYPE: 1CV2112B Low-voltage motor, IEC Squirrel-cage rotor, self-ventilated, IP55 Temperature class 155(F) according to 130(B) cast iron frame Performance line In EEA: Minimum efficiency acc. to applicable statutory regulations to be considered! (as of 01.01.2017) High Efficiency IE2, 4-pole * Size 112M, * 4kW (50 Hz) 4.55 kW (60 Hz) 3 AC 50 Hz 400 VD/690 VY * 3 AC 60 Hz 460 VD IM B 3, 3 PTC thermistors for disconnection (2 terminals) Terminal box at top B02=Acceptance test certificate 3.1 according to EN 10204

Main Menu