FAZT-C10/2 240855 EATON ELECTRIC Over current switch, 10A, 2p, C-Char, AC

 FAZT-C10/2

 EATON-MOELLER

Miniature circuit breaker (MCB), 10 A, 2p, characteristic: C

Compare

Miniature circuit breaker (MCB), 10 A, 2p, characteristic: C
Miniature circuit breaker (MCB), FAZ-T, 2-pole, tripping characteristic: C, rated current In: 10 A, Switchgear for industrial and advanced commercial applications

Delivery program

Basic function
Miniature circuit-breakers
Number of poles
2 pole
Tripping characteristic
C
Application
Switchgear for industrial and advanced commercial applications
Rated current [In]
10 A
Rated switching capacity acc. to IEC/EN 60947-2 [Icu]
25 kA
Product range
FAZ-T

Technical data

Electrical
Standards
IEC/EN 60947-2
EN 45545-2; IEC 61373
Rated voltage according to IEC/EN 60947-2 [Un]
415 V AC
Rated switching capacity acc. to IEC/EN 60947-2 [Icu]
25 kA
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 [Ics]
12,5 kA
Max operational voltage according to IEC/EN 60947-2
440 V AC
Rated switching capacity according to IEC/EN 60947-2 (max operational voltage) [Icu]
15 kA
Rated service short-circuit breaking capacity according to IEC/EN 60947-2 (max operational voltage) [Ics]
7,5 kA
Max operational voltage DC according to IEC/EN 60947-2
60/pole V DC
Rated voltage according to IEC/EN 60898-1 [Un]
415 V AC
Rated switching capacity according to IEC/EN 60898-1 [Icn]
15 kA
Rated service short-circuit breaking capacity according to IEC/EN 60898-1 [Ics]
7,5 kA
Rated insulation voltage [Ui]
440 V
Rated frequency [f]
50/60 Hz
Characteristic
B, C, D
Direction of incoming supply
as required
lifespanElectrical [Operations]
≧ 4000
lifespanMechanical [Operations]
≧ 10000
Mechanical
Standard front dimension
45 mm
Enclosure height
80 mm
Mounting width per pole
17.5 mm
Mounting
Quick attachment with 3 latch positions for top-hat rail IEC/EN 60715
Degree of Protection
IP20
Terminals top and bottom
Twin-purpose terminals
Terminal protection
Finger- and back-of-hand proof according to BGV A3 and ÖVE-EN 6
Terminal capacities
1 – 25 mm2
Tightening torque of fixing screws
max. 2.4 N/m
Thickness of busbar material
0.8 (exept N 0.5 SU) mm
Mounting position
As required

Additional information

part.no

FAZT-C10/2

current

Short Circuit

25

No of poles

2